What Should an Ideal Sterilization Room Look Like?
05 Ara, 2017
Clinic Management and Efficiency
What Should an Ideal Sterilization Room Look Like?
Sterilization quality is one of the most important behind-the-scenes elements that ensures the absolute treatment success of a clinic. Today, dental clinics pay more attention to sterilization processes and implement the arrangements required by these processes. In the past, when sterilization was mentioned, washing instruments in a container and then putting them in a hot air sterilizer came to mind. Apart from the handicaps such as wear and oxidation of instruments and inability to place grooved instruments, dry air sterilizers that do not fully provide sterilization safety have now become history. As the hygiene standard in treatments increased, the necessity and importance of steam sterilizers was understood, and steam and vacuum autoclaves began to replace dry air sterilizers in clinics. Many dentists who buy autoclaves mostly place this device on the counter in the examination room and proceed to the autoclaving stage after pre-cleaning in the same sink. This arrangement still continues in many practices. However, as sensitivities about sterilization increased and understanding developed, it began to be seen that this arrangement was not very adequate. Because it was understood that processing contaminated materials from previous patients in the same environment where the patient is present and treatment is performed, the coexistence of sterile/non-sterile, dirty/clean elements is not very suitable for sterilization management. Thus, the concept of "sterilization room" began to enter the literature of clinics.Sterilization Cycle and Room Design Relationship
Before moving on to how the sterilization room should be, it is necessary to determine the sterilization cycle because the room design is shaped according to this cycle. The whole process starts with treatment on the patient first. Of course, we assume that all elements used in treatment are sterile at the starting point. The following diagram summarizes the sterilization process.
There are basic assumptions in sterilization control; for example, all kinds of hand instruments, equipment, tips, etc. taken out and opened for a patient are considered contaminated even if they are not used on that patient. As the first task, materials considered to be contaminated should be separated into a different container and removed from the treatment area. These materials need to be pre-cleaned in an ultrasonic cleaner, residues and waste removed, and disinfected with disinfection solutions. These procedures can be performed manually as well as more healthily and quickly with devices that perform thermal disinfection and washing procedures together. Returning to room design at this stage of the process, first of all, there should be a sink counter with a wet floor. It is more appropriate for the counter to be made of stainless steel or water-resistant material. It is recommended that this counter be long enough to accommodate the ultrasonic cleaner, instrument trays and containers. If a machine is to be used for disinfection and washing, an appropriate place should be reserved under the counter, and water source, waste water outlet, and electrical connections should be planned according to the preferred device.
Previous Blog