MELAG Melatherm 10 Active Drying Thermal Disinfector
Product Code
DPAK-10021
Category
Sterilization
Group
Disinfection Unit
Brand
MELAG

Automatic Disinfectant Dosing, Active Drying, HEPA Filter
It is a Thermal Disinfection and Washing Device.

MELAG Melatherm 10 Active Drying Thermal Disinfector

The device applies pre-cleaning, cleaning, neutralizing, rinsing, and drying processes. In this process, a basic alkaline cleaning agent is used in the first stage, and an acidic cleaning agent is used to neutralize in the 2nd stage. In the 3rd stage, another substance is used for rinsing. In the 4th stage, washing is performed with hot water at 90 degrees for 5 minutes. In the final stage, active drying is provided with disinfected hot air.

After these processes, many hand instruments not related to blood or instruments without hollows can be used on the next patient without autoclaving. All viruses, bacteria, and fungi die in all these processes. Only organisms called spores survive; spores can only be destroyed by autoclaving. An instrument that is packaged and autoclaved can be stored sterile in the package for exactly 6 months without harboring any microorganisms after all these disinfection and sterilization processes.

90° washing and disinfection feature

Active drying with HEPA filter

Fast (disinfection times down to 32 minutes with "Quick Program")

84-liter internal volume

Capacity to wash up to 150 hand instruments of 30 patients at once

Automatic feeding of chemical agents with automatic dosing unit

Batch documentation via CF card or network connection

Melatherm 10 is compact; with a width of 60 cm, it can be easily mounted on many floor units or under the counter. If Melatherm is to be used free-standing, Melag offers the product with a stainless steel frame. Optionally, it is possible to place a storage unit on the bottom floor of the device. There is a basic basket in Melatherm 10. With a wide variety of trays and accessories available with or without rails, you can create content suitable for the clinic's needs.

Rail basket, instrument basket, flexible basket, impression tray rack, rack for articulated instruments, rack for 3 washing trays, 3 washing trays, small parts container, CF memory card, card reader Meladem 53 (optional)

It is possible to arrange optional content according to different dental or medical preferences.

The most important ones can be summarized as efficiency and savings.

The thermal disinfection device protects your instruments.

It protects the health of your assistant, your patients, yourself, and your nurses.

Instead, having them serve in customer satisfaction, calling a few patients to inquire about satisfaction, or inviting them for a check-up would be more efficient work for the clinic. In addition, the device is extremely environmentally friendly. It uses a few drops of disinfectant compared to manual disinfection. It always cleans your instruments to the same standard. It supports you in instrument preparation, quality, and disinfection standards.

Imagine a situation; a patient comes to you and says they have the AIDS virus, you take your precautions during the treatment, then you give the instruments you used in the treatment to your assistant and warn them: this patient has AIDS, be careful cleaning! Think of your assistant's facial expression. However, Melatherm 10 provides maximum infection control. The device applies pre-cleaning, cleaning, neutralizing, rinsing, and drying processes.

Stage: A basic alkaline cleaning agent is used.

Stage: Another acidic cleaning agent is used for neutralizing.

Stage: Another substance is used for rinsing.

Stage: Washing is performed with water at 90 degrees for 5 minutes.

All viruses, bacteria, and fungi die in all these processes. Only organisms called spores survive; but they do not have the risk of spreading disease. Spores can only be destroyed by autoclaving. In the final stage, active drying is provided with disinfected hot air. After these processes, many hand instruments not related to blood or instruments without hollows can be used on the next patient without autoclaving. An instrument that is packaged and autoclaved can be stored sterile in the package for exactly 6 months without harboring any microorganisms after these processes.

There is a connection tube in the device's chamber that heats the air and sprays it onto the instruments, thus providing active drying. Apart from its own dosing system and active drying system, it also has an integrated documentation system. It has an Ethernet card, can be connected to the network via cable. It has a CF card writer; disinfection data written to this card can be transferred to a computer in Microsoft Notepad or Word format. If you want to see the disinfection process as a graph, you can use software. Melaview software. Allows technical service to monitor the graph of the disinfection process.

You can put 4 to 6 of these baskets in the device with an internal volume of 84 liters. The device has an internal volume where you can place a total of 100-150 instruments of at least 30 patients. There are also slots where you can mount 11 hollow heads. It protects your instruments from corrosion and recontamination. That is, it protects them from getting dirty again after washing (active drying); the lid does not open before the temperature drops to 70 degrees in the device, so there is no risk of burning your hand.

Another advantage is that since the volume of the device is not very large, you do not need to wait a long time to fill the device, thus preventing chemical residues that dry and stick to your instruments as you wait from causing corrosion on the instruments.

The device has special baskets designed for other medical fields besides dentists. These are medical fields such as gynecology, otolaryngology, dermatology, urology, orthopedics, surgery.

<p>You can access other&nbsp;complementary dental sterilization products&nbsp;such as disinfection, sterilization, osmosis devices, demineralized water, packaging devices, test and documentation systems via this page. Our products are Melag and Morita branded and are offered with Metco Dental assurance.</p>

Internal and External Dimensions of the Device

Chamber internal dimensions:  45.5 (W) x 29 (H) x 42.3 (D) cm
External Dimensions (Under-counter model):  59.8 (W) x 81.8 (H) x 67.8 (D) cm
(H=max loading height, D= max loading depth)

Weight (kg): 79 kg

Door Feature: In the form of a lid opening forward

Door operating system: There is an electric motorized automatically locking door. When the door is closed, it locks automatically; when the open button is pressed, the lock is automatically released. The hinge movements of the lid are manual.

Chamber volume. Liters: 84 lt.

Stainless steel quality. (Chamber, Door, External Panels)

Chamber AISI 316 Ti stainless steel, electropolished. External cladding AISI 304 stainless steel and galvanized metal.

Printer connection

External printer can be connected. Disinfection logs and error messages can be printed.

Menu language: ENGLISH

Number of dosage pumps

There are 3 dosing pumps (2 for disinfection agents, 1 for rinsing agent)

Dosage pump level sensor: YES

Number of fixed programs: 5 fixed programs

Number of auxiliary programs

6 (5 for user, 1 for technical service)

Number of addable programs

None. Some parameters can be configured if necessary.

HEPA Filter: YES

External media connection possibilities

Has Ethernet port (RJ45) and built-in CF card writer. Date, time, batch no, temperatures and program stages can be documented.

Control panel features. LCD / Touch screen

Has LED screen. Program type, cycle stages, messages and warnings can be monitored from the 2 line 20 character screen.

Electrical information 380V/ 3N+PE,50 Hz Suitable for hospital mains electricity throughout Turkey.

AC 220-240 V3, 50Hz, 1x16A, 3.3kW

EN15883 certificate 

Has EN 15883 certificate. Processes operate according to the requirements of the standards.

Validation and calibration documents given by an accredited institution to be issued for each device

Factory test reports, validation documents, function operation reports indicating the serial number of each device are provided with the devices.

Package Content

Presented with Rail Basket, holding rack for articulated instruments, standard instrument basket, 3-compartment separator rack for trays or basket trays, small parts container.